Basic data | |||||||
---|---|---|---|---|---|---|---|
Series | 3C | ||||||
Operating principle | Reflection principle | ||||||
Special design | |||||||
Special design | Autocollimation, Teach input | ||||||
Optical data | |||||||
Operating range | 0 ... 2 m, With reflector MTKS 50x50.1 | ||||||
Operating range limit | 0 ... 3 m, With reflector MTKS 50x50.1 | ||||||
Light source | Laser, Red | ||||||
Laser class | 1, IEC/EN 60825-1:2007 | ||||||
Light-spot size [at sensor distance] | 1 mm [3,000 mm] | ||||||
Shift angle | Typ. ± 2° | ||||||
Electrical data | |||||||
Protective circuit | Polarity reversal protection, Short circuit protected | ||||||
Performance data | |||||||
Supply voltage UB | 10 ... 30 V, DC, Incl. residual ripple | ||||||
Residual ripple | 0 ... 15 %, From UB | ||||||
Open-circuit current | 0 ... 15 mA | ||||||
Protective circuit | Polarity reversal protection, Short circuit protected | ||||||
Inputs | |||||||
Number of teach inputs | 1 Piece(s) | ||||||
Protective circuit | Polarity reversal protection, Short circuit protected | ||||||
Outputs | |||||||
Number of digital switching outputs | 1 Piece(s) | ||||||
Switching output 1 | |||||||
Switching element | Transistor, PNP | ||||||
Switching principle | Light switching | ||||||
Number of digital switching outputs | 1 Piece(s) | ||||||
Protective circuit | Polarity reversal protection, Short circuit protected | ||||||
Timing | |||||||
Switching frequency | 3,000 Hz | ||||||
Response time | 0.17 ms | ||||||
Connection | |||||||
Connection 1 | |||||||
Type of connection | Cable with connector | ||||||
Function | Voltage supply, Signal IN, Signal OUT | ||||||
Cable length | 200 mm | ||||||
Thread size | M8 | ||||||
Material | Metal | ||||||
No. of pins | 4 -pin | ||||||
Mechanical data | |||||||
Dimension (W x H x L) | 11.4 mm x 34.2 mm x 18.3 mm | ||||||
Housing material | Plastic, PC-ABS | ||||||
Lens cover material | Plastic / PMMA | ||||||
Net weight | 20 g | ||||||
Type of fastening | Via optional mounting device, Through-hole mounting | ||||||
Compatibility of materials | ECOLAB | ||||||
Operation and display | |||||||
Operational controls | Teach button | ||||||
Environmental data | |||||||
Ambient temperature, operation | -40 ... 55 °C | ||||||